Model: RD6006

Loading locations...

About the Product

Product Description

RD6006
  • Input voltage range: 6-70.00V
  • Output voltage range: 0-60.00V
  • Output current range: 0-6.000A
  • Output power range: 0-360.0W
  • Output voltage accuracy: ±(0.3%+3 digits)
  • Input voltage accuracy:±(1%+5 digits)
  • Output ripple typical: 100mV VPP
  • Constant voltage mode response time:2ms?0.1A-5A load)
  • Constant voltage mode load adjustment rate : ±(0.1%+2 digits)
  • Constant current mode load adjustment rate: ±(0.1%+3 digits)
  • Screen brightness setting:0-5 level total 6 levels
  • Weight(with package): 607g
  • Product dimension:167*81*65mm
  • Display Screen:2.4 inch color LCD display
  • Input voltage measurement resolution: 0.01V
  • Output voltage measurement resolution: 0.01V
  • Current setting measurement resolution: 0.001A
  • Battery voltage measurement resolution: 0.01V
  • Output current accuracy: ±(0.5%+5 digits)
  • Battery voltage measurement accuracy:±(0.5%+3 digits)
  • Working temperature range:-10?~40?
  • External sensor Temperature detection range:-10?~100?/0?~200?
  • External sensor Temperature detection accuracy:± 3?/ ± 6?
  • Capacity measurement range:0-9999.99Ah
  • Energy measurement range:0-9999.99Wh
  • Capacity and energy statistical error: ±2?
  • Working mode: Buck mode
  • Voltage drop >1V and >10%

RD6006P-W
  • Input Voltage Range: 7-70.00V
  • Output Voltage Range: 0-60.000V
  • Output Current Range: 0-6.0000A
  • Output Power Range: 0-360.00W
  • Input Voltage Measurement Resolution: 0.01V
  • Output Voltage Setting Measurement Resolution: 0.001V
  • Output Current Setting Measurement Resolution: 0.0001A
  • Battery Voltage Measurement Resolution: 0.01V
  • Input Voltage Measurement Accuracy: ±(1% + 5 digits)
  • Output Voltage Accuracy Between Setting and Measurement: ±(0.5% + 4 digits)
  • Output Current Accuracy Between Setting and Measurement: ±(1% + 6 digits)
  • Battery Voltage Measurement Accuracy: ±(0.5% + 3 digits)
  • Automatic Cutoff Current Value When Charging: Set by yourself
  • Output Ripple Typical: 20mV VPP
  • Working Temperature Range: -10°C ~ 40°C
  • External Sensor Temperature Detection Range: -10°C ~ 100°C / 0°F ~ 200°F
  • External Sensor Temperature Detection Accuracy: ±3°C / ±6°F
  • Constant Voltage Mode Response Time: 2ms (0.1A-5A Load)
  • Constant Voltage Mode Load Regulation: ±(0.1% + 2 digits)
  • Constant Current Mode Load Regulation: ±(0.1% + 3 digits)
  • Capacity Measurement Range: 0-9999.99Ah
  • Energy Measurement Range: 0-9999.99Wh
  • Capacity and Energy Statistical Error: ±2%
  • Buck Working Mode Voltage Drop: >10% * VOUT + 2V
  • Cooling Fan Start Condition: Output Current >4A or System Temperature >45°C
  • Cooling Fan Shut Down Condition When Working: Output Current <3.9A and System Temperature <45°C
  • Over Temperature Protection: System Temperature >80°C
  • Screen Brightness Setting: 0-5 (6 levels)
  • Screen: 2.4-inch Color HD Display
  • Weight (With Package): About 0.62Kg
  • Product Dimension: 167 × 81 × 65 mm
  • Support USB Communication: Yes
  • Support WiFi Communication: Yes (RD6006P-W)

400W 65V Switching Power Supply
  • Input Voltage: 100-120V/200-240V AC
  • Voltage: 65V
  • Adjustable: ±5%
  • Power: 400W
  • Size: 215x115x50mm
View Product Details
You might like